PyPSA spillage — water a reservoir cannot hold

A hydro unit takes inflow it did not choose, and spills what neither turbine nor reservoir can absorb.

✔ Verified against pypsa 1.2.4 (its own linopy 0.9.0) — objective 3200.0, matched to rtol=1e-09.

inflow is energy that arrives whether or not the model wanted it. When the reservoir is full and the turbine is at its limit, the energy balance closes only if something lets the surplus go. That is spill.

Two storage units share the bus: res receives inflow, bat receives none. The battery absorbs water that would otherwise be spilled, so neither unit is decoration.

The model

The same model, as math

PyPSA storage spillage: water a reservoir cannot hold leaves through a second sink. A hydro unit takes inflow it did not choose and spills what neither its turbine nor its reservoir can absorb; a battery beside it has no inflow, and so no spill variable at all. Optimum 3200.0, from PyPSA itself.

Sets

Symbol Meaning
\(\mathcal{T}\) index \(t\) — snapshot — dispatch periods
\(\mathcal{B}\) index \(b\) — bus with \(\mathrm{gen\_bus}: \mathcal{G} \to \mathcal{B},\ \mathrm{storage\_bus}: \mathcal{S} \to \mathcal{B}\) — network nodes
\(\mathcal{G}\) index \(g\) — generator with \(\mathrm{gen\_bus}: \mathcal{G} \to \mathcal{B}\) — generating units, each sitting on one bus
\(\mathcal{S}\) index \(s\) — storage with \(\mathrm{storage\_bus}: \mathcal{S} \to \mathcal{B}\) — storage units, each sitting on one bus

Parameters

Symbol Meaning
\(\mathrm{p}^{\mathrm{nom}}\) p_nom over \(\mathcal{G}\) — installed capacity of a generator
\(\mathrm{marginal\_cost}\) marginal_cost over \(\mathcal{G}\) — cost of one unit of output
\(\mathrm{storage\_p\_nom}\) storage_p_nom over \(\mathcal{S}\) — most a storage unit may charge or discharge in one snapshot
\(\mathrm{soc}^{\mathrm{max}}\) soc_max over \(\mathcal{S}\) — how much energy a storage unit holds when full
\(\mathrm{soc}^{\mathrm{initial}}\) soc_initial over \(\mathcal{S}\) — energy in the store before the first snapshot
\(\mathrm{inflow}\) inflow over \(\mathcal{T} \times \mathcal{S}\) — energy arriving at a storage unit whether or not it was wanted — zero for a unit that receives none
\(\mathrm{load}\) load over \(\mathcal{T} \times \mathcal{B}\) — demand at each bus in each snapshot

Variables

Symbol Meaning
\(p\) p over \(\mathcal{T} \times \mathcal{G}\) — output of a generator in a snapshot
\(p^{\mathrm{dispatch}}\) p_dispatch over \(\mathcal{T} \times \mathcal{S}\) — power a storage unit puts onto its bus
\(p^{\mathrm{store}}\) p_store over \(\mathcal{T} \times \mathcal{S}\) — power a storage unit takes off its bus
\(\mathit{soc}\) soc over \(\mathcal{T} \times \mathcal{S}\) — energy in the store at the end of a snapshot
\(\mathit{spill}\) spill over \(\mathcal{T} \times \mathcal{S}\) — inflow let go rather than kept, and never more than that snapshot's arrival. A unit that receives no inflow has none to let go, which is a spill of zero rather than a quantity with no value — so the energy balance keeps its row there.

Upright is what the data supplies — a parameter such as \(\mathrm{p}^{\mathrm{nom}}\), a coordinate map, a label — and italic is what the solver chooses, such as \(p\). An index is italic too, being what a quantifier chooses, and a set is script.

\(\mathrm{pos}(t)\) denotes where index \(t\) sits along its dimension's own order — the order shift steps along, not the order labels sort in — counted from \(0\). The index itself stays the coordinate, so \(t\) compares against labels and \(\mathrm{pos}(t)\) against positions.

Objective

\[ \min \sum_{t \in \mathcal{T},\ g \in \mathcal{G}} p_{t,g} \cdot \mathrm{marginal\_cost}_{g} \]

Subject to

nodal_balance

\[ \sum_{g \in \mathcal{G} \,:\, \mathrm{gen\_bus}(g) = b} p_{t,g} + \sum_{s \in \mathcal{S} \,:\, \mathrm{storage\_bus}(s) = b} p^{\mathrm{dispatch}}_{t,s} - \left( \sum_{s \in \mathcal{S} \,:\, \mathrm{storage\_bus}(s) = b} p^{\mathrm{store}}_{t,s} \right) = \mathrm{load}_{t,b} \qquad \forall\, t \in \mathcal{T},\ b \in \mathcal{B} \]

energy_balance_initial

\[ \mathit{soc}_{t,s} = \mathrm{soc}^{\mathrm{initial}}_{s} + p^{\mathrm{store}}_{t,s} - p^{\mathrm{dispatch}}_{t,s} + \mathrm{inflow}_{t,s} - \mathit{spill}_{t,s} \qquad \forall\, t \in \mathcal{T},\ s \in \mathcal{S} \,:\, \mathrm{pos}(t) = 0 \]

energy_balance

\[ \mathit{soc}_{t,s} = \mathit{soc}_{t - 1,s} + p^{\mathrm{store}}_{t,s} - p^{\mathrm{dispatch}}_{t,s} + \mathrm{inflow}_{t,s} - \mathit{spill}_{t,s} \qquad \forall\, t \in \mathcal{T},\ s \in \mathcal{S} \]

Variable domains

p

\[ 0 \le p_{t,g} \le \mathrm{p}^{\mathrm{nom}}_{g} \qquad \forall\, t \in \mathcal{T},\ g \in \mathcal{G} \]

p_dispatch

\[ 0 \le p^{\mathrm{dispatch}}_{t,s} \le \mathrm{storage\_p\_nom}_{s} \qquad \forall\, t \in \mathcal{T},\ s \in \mathcal{S} \]

p_store

\[ 0 \le p^{\mathrm{store}}_{t,s} \le \mathrm{storage\_p\_nom}_{s} \qquad \forall\, t \in \mathcal{T},\ s \in \mathcal{S} \]

soc

\[ 0 \le \mathit{soc}_{t,s} \le \mathrm{soc}^{\mathrm{max}}_{s} \qquad \forall\, t \in \mathcal{T},\ s \in \mathcal{S} \]

spill

\[ 0 \le \mathit{spill}_{t,s} \le \mathrm{inflow}_{t,s} \qquad \forall\, t \in \mathcal{T},\ s \in \mathcal{S} \,:\, \mathrm{inflow}_{t,s} \neq 0 \]

The tabs start from the instance's tables — one frame per parameter.

description: >-
  PyPSA storage spillage: water a reservoir cannot hold leaves through a second
  sink. A hydro unit takes inflow it did not choose and spills what neither its
  turbine nor its reservoir can absorb; a battery beside it has no inflow, and
  so no spill variable at all. Optimum 3200.0, from PyPSA itself.

dimensions:
  snapshot:
    description: dispatch periods
    dtype: int
  bus:
    description: network nodes
    dtype: str
  generator:
    description: generating units, each sitting on one bus
    dtype: str
  storage:
    description: storage units, each sitting on one bus
    dtype: str

relations:
  gen_bus:
    description: the bus a generator sits on
    key: generator
    values: bus
  storage_bus:
    description: the bus a storage unit sits on
    key: storage
    values: bus

parameters:
  p_nom:
    description: installed capacity of a generator
    dims: [generator]
  marginal_cost:
    description: cost of one unit of output
    dims: [generator]
  storage_p_nom:
    description: most a storage unit may charge or discharge in one snapshot
    dims: [storage]
  soc_max:
    description: how much energy a storage unit holds when full
    dims: [storage]
  soc_initial:
    description: energy in the store before the first snapshot
    dims: [storage]
  inflow:
    description: >-
      energy arriving at a storage unit whether or not it was wanted — zero for
      a unit that receives none
    dims: [snapshot, storage]
  load:
    description: demand at each bus in each snapshot
    dims: [snapshot, bus]

variables:
  p:
    description: output of a generator in a snapshot
    dims: [snapshot, generator]
    bounds:
      lower: 0
      upper: p_nom
  p_dispatch:
    description: power a storage unit puts onto its bus
    dims: [snapshot, storage]
    bounds:
      lower: 0
      upper: storage_p_nom
  p_store:
    description: power a storage unit takes off its bus
    dims: [snapshot, storage]
    bounds:
      lower: 0
      upper: storage_p_nom
  soc:
    description: energy in the store at the end of a snapshot
    dims: [snapshot, storage]
    bounds:
      lower: 0
      upper: soc_max
  spill:
    description: >-
      inflow let go rather than kept, and never more than that snapshot's
      arrival. A unit that receives no inflow has none to let go, which is a
      spill of zero rather than a quantity with no value — so the energy
      balance keeps its row there.
    dims: [snapshot, storage]
    where: "inflow != 0"
    absence: zero
    bounds:
      lower: 0
      upper: inflow

constraints:
  nodal_balance:
    description: >-
      what is generated at a bus, plus what comes out of the stores less what
      goes into them, meets the load there
    dims: [snapshot, bus]
    expression: >-
      sum(p, by=gen_bus, over=generator, into=bus)
      + sum(p_dispatch, by=storage_bus, over=storage, into=bus)
      - sum(p_store, by=storage_bus, over=storage, into=bus)
      == load

  energy_balance_initial:
    description: the first snapshot's level is carried from the initial state of charge
    dims: [snapshot, storage]
    where: "position(snapshot) == 0"
    expression: soc == soc_initial + p_store - p_dispatch + inflow - spill

  energy_balance:
    description: >-
      the level carried into a snapshot, plus what was stored and what arrived,
      less what was taken and what was let go
    dims: [snapshot, storage]
    expression: >-
      soc == shift(soc, along=snapshot, offset=1)
      + p_store - p_dispatch + inflow - spill

objective:
  sense: minimize
  description: total cost of generation; storage and spillage are free here
  expression: sum(p * marginal_cost)
# sources: parameter name -> frame or parquet path
with sps.solve('examples/ports/pypsa_spill.yaml', sources) as solution:
    solution.objective  # 3200.0
    solution.dual('nodal_balance')

The model-building half of examples/ports/references/pypsa/pypsa_spill.py:

def build(tables: dict[str, pd.DataFrame]) -> pypsa.Network:
    """The port's tables as a PyPSA network, column for column.

    ``tables`` is the same mapping the specsolve call attaches as ``sources``.

    ``inflow`` is a time-varying attribute, so it arrives pivoted to snapshots
    by names. PyPSA declares the spill variable only for units whose inflow is
    positive somewhere; the port declares it for every unit and bounds it above
    by the inflow, which pins it to zero for the battery. Same model, and the
    port's spelling is the one that keeps the energy balance a single block.
    """
    n = pypsa.Network()
    n.set_snapshots(tables['snapshot']['snapshot'])
    n.add('Bus', tables['bus']['bus'])

    generators: pd.DataFrame = tables['generator'].set_index('generator')
    storages: pd.DataFrame = tables['storage'].set_index('storage')
    n.add(
        'Generator',
        generators.index,
        bus=generators['gen_bus'],
        p_nom=tables['p_nom'].set_index('generator')['value'],
        marginal_cost=tables['marginal_cost'].set_index('generator')['value'],
    )

    p_nom: pd.Series = tables['storage_p_nom'].set_index('storage')['value']
    n.add(
        'StorageUnit',
        storages.index,
        bus=storages['storage_bus'],
        p_nom=p_nom,
        max_hours=tables['soc_max'].set_index('storage')['value'] / p_nom,
        state_of_charge_initial=tables['soc_initial'].set_index('storage')['value'],
        inflow=tables['inflow']
        .pivot(index='snapshot', columns='storage', values='value')
        .reindex(columns=storages.index)
        .fillna(0.0),
        cyclic_state_of_charge=False,
    )

    load: pd.DataFrame = tables['load'].pivot(index='snapshot', columns='bus', values='value')
    for bus in tables['bus']['bus']:
        n.add('Load', f'load_{bus}', bus=bus, p_set=load[bus])
    return n

Spilling is forced, not chosen. Snapshot 1 opens with a full 60 MWh reservoir and 50 MWh more arriving against a 30 MW turbine. At least 20 MWh has to go. Total gas burn is then pinned at 20 + spill = 40 MWh, which is the entire objective. A port that dropped the spill variable would be infeasible rather than wrong.

The battery has no spill decision at all. PyPSA declares the spill variable only for units whose inflow is positive somewhere. The port matches that with where: "inflow != 0", so spill has six coordinates rather than twelve.

The mask is safe only because of the line beside it. A constraint mentioning a masked variable loses its row, not only the term. On its own the mask would delete the battery's whole energy balance. Its stored energy would come from nowhere, and the model would report 0.0 instead of 3200. absence: zero says the missing coordinates hold a spill of zero rather than a quantity with no value, so the row stands without the term.

The mask compares a value rather than naming the parameter. where: inflow would be a no-op here: a where: on a bare parameter reads defined and finite, and the padded 0.0 is both. Nor can the zeros be dropped from the table. inflow is a term on the energy balance's constant side, and a sparse parameter there is refused at load. A missing row read as zero would be a bound rather than an absence. The sparsity that matters is in the value, and != 0 is how the model asks for it.

What it exercises

absence: zero on a masked variable, the declaration that keeps a row whose term has gone, against an energy balance carrying two independent sinks. Also the asymmetry underneath it: a masked variable takes its row, while a sparse parameter on a constant side is refused. The two halves of this model's sparsity are spelled in two different ways.